AUTOCLAVE PRESOCLAVE II PLUS 150L 400V 50/60Hz

  • Size Guide

    Size Guide

    SIZE CHEST WAIST HIPS
    XS 34 28 34
    S 36 30 36
    M 38 32 38
    L 40 34 40
    XL 42 36 42
    2XL 44 38 44
  • Delivery Return

    Delivery

    We ship to all 50 states, Washington DC.
    All orders are shipped with a UPS tracking number.
    Always free shipping for orders over US $200.
    During sale periods and promotions the delivery time may be longer than normal.

    Return

    Fana will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period), on presentation of the original till receipt at any store where the corresponding collection is available within the country of purchase.

    Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed.
    Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.

    Help

    • Give us a shout if you have any other questions and/or concerns.
    • Email: contact@mydomain.com
    • Phone: +1 (23) 456 789
  • Ask a Question

Free

Worldwide
Shopping

100%

Guaranteed
Satisfaction

30 Days

Guaranteed
Money Back

Capacidad: 150 litros.
Control de temperatura y ciclo por microprocesador y purgado por vacío fraccionado.
Regulación electrónica de la temperatura y tiempo con lectura digital y purgado atmosférico.
Para temperaturas desde 115 °c hasta 134 °c (0,62 a 2 bar).
Conforme a las directivas de aparatos de presión.
Registro de proceso y descarga via usb.
Modelo vertical.
Capacidad: 150 litros.

PRINCIPIO
LA ESTERILIZACIÓN ES EL PROCESO MEDIANTE EL CUAL SE ALCANZA LA DESTRUCCIÓN O ELIMINACIÓN DE TODAS LAS FORMAS DE VIDA
MICROBIANAS INCLUYENDO LAS BACTERIAS Y SUS ESTRUCTURAS.
EL AUTOCLAVE DE LABORATORIO ESTÁ FORMADO POR UN RECIPIENTE EN EL QUE EL VAPOR CIRCULA A ALTA PRESIÓN Y QUE TIENE LA FINALIDAD DE LA ESTERILIZACIÓN. EL VAPOR SATURADO SE CONDENSARÁ INMEDIATAMENTE LIBERANDO SU ALTO CALOR DE EVAPORIZACIÓN Y
QUE ES EL AGENTE DESTRUCTIVO. PARA QUE UNA ESTERILIZACIÓN SEA EFECTIVA, EL VAPOR DEBE SATURARSE Y POR CONSIGUIENTE DEBE PURGARSE TODO EL AIRE DEL INTERIOR DE LA CÁMARA ANTES DE INICIAR EL PROCESO.

PANEL DE MANDOS
1. Pantalla TFT táctil con pulsadores virtuales.
2. Manómetro.
3. Mando apertura tapa.
PARTE POSTERIOR
1. Válvula de seguridad.
2. Toma de red eléctrica.
3. Termostato de seguridad.
4. Salida vaciado de vapor y de drenaje.
5. Conector USB.

SEGURIDAD
VÁLVULA DE SEGURIDAD: PREVIENE QUE LA PRESIÓN SOBREPASE EL LÍMITE MÁXIMO.
PRESOSTATO DE SEGURIDAD: DESCONECTA LOS CALEFACTORES EN CASO DE SOBREPASAR EL LÍMITE DE PRESIÓN.
TERMOSTATO DE SEGURIDAD: DESCONECTA LA CALEFACCIÓN EN CASO DE SOBRETEMPERATURA O FALTA DE AGUA EN EL DEPÓSITO.
DISPOSITIVO TAPA: IMPIDE LA APERTURA DE LA TAPA MIENTRAS LA CÁMARA SE ENCUENTRA BAJO PRESIÓN.
ENVOLVENTE DE PROTECCIÓN TÉRMICA DE LA TAPA.

CARACTERÍSTICAS
Mueble exterior y encimera en acero inox.
Elemento calefactor en acero inox. especial INCOLOY de gran duración, resistente a la corrosión y a la alta temperatura.
Registro de proceso y descarga via USB.
Debido a su consumo se fabrica para corriente trifásica a 230 V ó 400 V a especificar.
Depósito, tapa y cierre en acero inox.
Purgado atmosférico automático.
10 programas configurables por el usuario.
Se suministran sin cestillos y sin tambores.
Se pueden adquirir accesorios (cestillos de alambre y tambores de acero inox. AISI 304) y complementos a instalarse en fábrica (sonda Pt100) por separado previa solicitud.